WaterLeveller installation
This guide is for the current WaterLeveller sensor, which looks like a black dipstick. If yours looks like a white PVC tube, follow the legacy installation guide. Use the sensor with the matching control box.
Reference diagram
General information
What’s in the kit
- WaterLeveller control box
- Factory-calibrated water-level sensor and cable
- Split collar clamp
- Solenoid valve and connecting cable
- Power adaptor
Water-level sensing pipe
For the pool or spa layout shown, the sensor sits in a vertical pipe connected to the pool or spa, so the water in the pipe follows the same level. Your installer supplies a cap that fits the pipe and lets the sensor move to the required depth. Use the supplied split collar clamp to hold the sensor in position at the cap.
Water inlet
Identify the refill water supply and fit an accessible manual stop valve. Your installer should confirm the inlet layout and backflow protection for your site. The diagram shows a dedicated refill inlet with an air gap. Follow the flow arrow on the solenoid valve when fitting it.
Power and control box placement
Choose a mounting point near the switched power outlet, valve and sensing pipe so the supplied leads reach their labelled sockets. Keep the power off while you make the connections.
Installation instructions
1. Prepare the pool or spa
Bring the water to the highest level you want WaterLeveller to maintain. Mount the control box, fit the solenoid valve to the refill line and leave the manual stop valve closed while making the connections.
2. Fit and connect the sensor
With the control box switched off, connect the valve, sensor and supplied power adaptor to their labelled sockets. Fit the installer-selected cap to the sensing pipe and position the sensor through it. Fit the split collar clamp so it can hold the sensor at the cap once you set the depth. Start with the sensing areas above the water and leave enough movement to adjust the depth.
Plug the sensor in before switching on the control box. The sensor is factory-calibrated. Starting the box with the sensor unplugged opens calibration mode.
3. Set the upper water level in installer mode
Open the manual stop valve and switch on the control box. The green power light flashes evenly during the ten-minute installer window. The solenoid should open while the sensing areas are dry. Lower the sensor slowly into the sensing pipe, pausing to let it respond. When the valve closes and the valve status light goes out, tighten the split collar clamp to hold the sensor at that height on the cap.
Use the high notch as the stop-level reference. The low notch marks the level below which WaterLeveller calls for a refill.
4. Check that the valve opens and closes
Keep the height adjustment secured. Lift the sensor out, wipe it dry and check that the solenoid opens. Put it back into the water and check that the solenoid closes, then return it to its set position. If water continues to flow, close the manual stop valve and contact support.
The green light becomes steady when installer mode ends. For another installer window, switch the box off, wait for the power light to go out, then switch it back on with the sensor connected.
See sensor maintenance for the periodic check or sensor calibration if you need to recalibrate the sensor.